The Welch Allyn CP 150 Electrocardiograph (ECG) offers simplicity with speed using a unique, 7" touch-screen display and keyboard — helping to improve accuracy. To meet the needs of fast-paced environments, take quick ECG readings with the touch of a button. And with a range of advanced connectivity features, help improve your practice workflow by sending, managing, and sharing patient data with systems inside or outside your facility.
- 7” Color, touch screen display for fast and easy entry of accurate patient information
- Instant-on feature powers the device up quickly and lets you take an ECG at a moment’s notice
- Advanced filters for optimal ECG trace quality ensure accurate readings
- Three (3) lead ECG preview
- Optional adult and pediatric MEANS ECG interpretation software offers a second opinion
- Battery operation lets you easily transport your device to the patient
- Store up to 100 test results on the device or transfer to a USB memory stick
- Dimensions, including rubber feet: 15" (380.9 mm) x 14.1" (358.1 mm) x 5.4" (136.2 mm)
- Weight, including batter:y 11.5 lb (5.2 kg)
- Keyboard type (power button): Polyester overlay
- Display: Type: TFT, 18 cm (7 in.) color touch screen; Resolution: WVGA, 800 x480
- Thermal paper: Z-fold, 8.25 x 11 inches (21 x 28 cm), 200 sheets
- Thermal printer (internal): Computer-controlled dot array, 8 dots/mm
- Thermal-chart-paper speeds: 10, 25, 50 mm/s
- Gain settings: Auto ECGs: 2.5, 5, 10, 20 mm/mV, Auto; Rhythm ECGs: 2.5, 5, 10, 20 mm/mV
- Lead configurations: Standard, Cabrera
- Report formats, internal printer, Auto report: 3x4-2.5s @ 25 mm/s; 3x4-2.5s @ 50 mm/s; 3x4+1R-2.5s @ 25 mm/s; 3x4+3R-2.5s @ 25 mm/s; 3x4-5.0s @ 25 mm/s; 3x4-5.0s @ 50 mm/s; 6x2-5.0s @ 25 mm/s; 6x2-5.0s @ 50 mm/s; 12x1-10.0s @ 25 mm/s
- Report formats, internal printer, Average: 3x4+3R @ 25 mm/s; 3x4+3R @ 50 mm/s; 6x2+1R @ 25 mm/s; 6x2+1R @ 50 mm/s; No print
- ECG storage (in test directory): At least 100 ECG tests
- Patient storage: Up to 50 patients
- Frequency range: 0.3 to 150 Hz
- Digital sampling rate: > 1,000 samples/second/channel
- Pacemaker detection: ANSI/AAMI EC11
- Power requirement: Universal AC power supply 110-240 V~, 50/60 Hz ~, 1.5 A maximum
- AC fuses: Time-lag type, 2.0-amp 250-V rating, Littelfuse 0218002P or equivalent
- Rechargeable battery, 9 cells: Rating: 10.8 V 6.75Ah (73Wh); Composition: Lithium-ion; Recharge time to 100 percent capacity: 4 hrs; Full charge capacity: 25 ECG tests @ 20 minutes per test
- 8 hrs of continuous operation or 250 continuous ECGs
- Filters: High-performance baseline: 0.5 Hz; Muscle tremor: 35 Hz
- AC interference: 50 Hz or 60 Hz
- Safety, EMC, and regulatory compliance: ANSI/AAMI EC11**: IEC/EN 60601-1; CAN/CSA C22.2 No. 601.1: IEC/EN 60601-1-2; CAN/CSA C22.2 No. 601.1.2: IEC/EN 60601-1-4; CAN/CSA C22.2 No. 601.1.4: IEC/EN 60601-1-6; CAN/CSA C22.2 No. 601.2.25: IEC/EN 60601-2-25***, IEC/EN 60601-2-51* (3x4 report format)
- Standard connectivity: 1 USB client, 4 USB hosts
- Connectivity with electronic medical records: Through the Welch Allyn CardioPerfect workstation software
- Electrodes: Rigorously tested for conductivity, adhesion, and hypoallergenic qualities, and exceed all AAMI standards
- Power cable: Meets or exceeds Type SJT.
- Environmental operating conditions: Temperature: +10° C to +40° C (+50° F to +104° F); Relative humidity: 15 - 95% noncondensing (30 - 70% for printing); Atmospheric air-pressure limits: 700 - 1060 hPa
- Environmental storage conditions: Temperature: -20° C to +50° C (-4° F to +122° F); Relative humidity: 15 - 95% noncondensing; Atmospheric air-pressure limits 700 - 1060 hPa
- Protection against electric shock: Class I, internally powered Type CF
- Mode of operation: Continuous
* If you print at a high gain setting, the waveform or calibration marks might be clipped. This clipping does not comply with clause 51.103.1 of the IEC/EN 60601-2-51 standard. Use a lower gain setting to observe the full waveform.
** Per AAMI EC11:1991/®)2007 Diagnostic Electrocardiographic Devices, Section 3.1.2.1 Disclosure of cautionary information/ performance characteristics paragraph c) Accuracy of input signal reproduction, the manufacturer shall disclose the methods used to establish overall system error and frequency response. Welch Allyn has used methods A & D, as prescribed in section 3.2.7.2 and 4.2.7.2 of this same standard, to verify overall system error and frequency response. Because of the sampling characteristics and the asynchronism between sample rate and signal rate, digital ECG systems such as the CP 150 may produce a noticeable modulating effect from one cycle to the next, particularly in pediatric recordings. This phenomenon is not physiologic.
*** Disposable electrodes from Welch Allyn shall be used during patient defibrillation.